Product Overview
Bijur Delimon TMD-5 Lubricator
Bijur Delimon 32295 Lubricator TMD5 27MN 2L Black 24 VDC
Part Number / SKU: 32295 | Manufacturer: Bijur Delimon | Availability: Made to Order - Lead Time: 83-93 business days
Overview
Bijur Delimon 32295 (factory description: LUB TMD5 27MN 2L BLK 24VDC). Bijur TMD-5 automatic cyclic lubricators: a gear-reduction motor drives a spring-discharge piston pump that sends an adjustable oil shot to Type F meter units at a fixed interval; low-level switch standard.
Specifying, quoting, or replacing 32295
Add to cart at the price shown, or use the Request a Quote form: send the part number 32295, the quantity, and a photo of the nameplate or the old part, and we reply the same day. L. DeWitt McCarter is an authorized Bijur Delimon, Farval and LubeSite distributor in San Antonio, TX — (210) 494-1997.
Key Specifications
| Manufacturer part number | 32295 |
| Brand | Bijur Delimon |
| Selling unit | Each (1 piece) |
| Discharge per cycle | 1-5 cc adjustable (collar with indicator window) |
| Discharge pressure | 4.1 bar (60 psi) max |
| Reservoir | 1.8 L (110 cu in), plastic |
| Viscosity | 27-1700 cSt (150-8000 SSU) |
| Suction filter | 40 µm nominal |
| Outlet port | 5/16-24 female for 4 mm (5/32 in) tube; tighten to 3.4 N·m (30 in-lb) |
| Protection / temp | IP52; 5-40 °C (40-105 °F) |
| Low-level switch | Standard; 10 W max; factory N.O., invert float for N.C. |
| Supply | 24 VDC, 33 mA average |
| Cycle | 33.2 min (50 Hz) / 27.7 min (60 Hz) timing |
What You'll Also Need
- 25 µm line filter in the main line near the lubricator whenever meter units are used: 19850 (1 in) or 19848 (3 in) (DS 24117)
- Pressure gauge B5610 (0-100 psi) downstream of the filter for a visual cycle check (DS 24117)
- Pressure switch for electronic monitoring: 26410 (SPST N.O., 12 psi) or 26393 (SPST N.C., 10 psi) (DS 24117)
- Spare filter group kit 26361 (spring clip 20577, filter disc B3747, filter screen B3746) (DS 24117)
- Type F meter units, one per lube point (DS 35470)
Before You Order
- Store names say 2L; DS 24117 and 005-B give the reservoir as 1.8 liters.
- Cycle time is fixed by the motor: 26350-1 to -6 run 6.4 to 128 min at 50 Hz (5.3 to 106.7 min at 60 Hz). Pick the dash number for the interval you need (DS 24117).
- The main supply must be fused; the lubricator has no internal protection (DS 24117).
- Not for explosive atmospheres or for pumping highly flammable liquids (DS 24117).
- Leave 115 mm (4.5 in) below the reservoir for removal; the mounting surface must carry 3.4 kg (7.5 lb) (DS 24117).
- For 230 VAC, hot goes to terminal 4 and the suppressor wire moves from terminal 5 to 4 (DS 24117).
Choosing Between Options
- TMD-5 covers 1-5 cc per cycle; for 0.2-1.0 cc use TM-1 (DS 24117; DS 35477).
- Replacing an obsolete TM-5: the TMD-5 has the same 1-5 cc piston-pump range; BDI also offers special SureFire II SFX71322-RK/-BK (DS 24117; TS020).
- 24 VDC supply: 32295 (27.7 min at 60 Hz) is the only DC model (DS 24117).
Product Documentation
Opens in your browser — use your browser's save option to download a copy.
Browse all Bijur Delimon products or request a quote for 32295 — we reply the same day.