Product Overview
Bijur Delimon Controls & Monitoring
Bijur Delimon 34210 Switch Pressure with DIN 300 PSI N/O
Part Number / SKU: 34210 | Manufacturer: Bijur Delimon | Availability: In Stock at Factory - Ships in 3-5 Business Days
Overview
Bijur Delimon 34210 (factory description: SWTCH PRESS W/DIN 300 PSI N.O.). Pressure switches that open or close an electrical contact at a set lubricant or air pressure, used to confirm a lube cycle, detect end-of-line pressure or monitor air supply.
Specifying, quoting, or replacing 34210
Add to cart at the price shown, or use the Request a Quote form: send the part number 34210, the quantity, and a photo of the nameplate or the old part, and we reply the same day. L. DeWitt McCarter is an authorized Bijur Delimon, Farval and LubeSite distributor in San Antonio, TX — (210) 494-1997.
Key Specifications
| Manufacturer part number | 34210 |
| Brand | Bijur Delimon |
| Selling unit | Each (1 piece) |
| Catalog listing | DIN-style pressure switches, IP65 (35859 NEMA 4/13), -40° to 225°F |
| Set psi | 300 |
| bar | 20 |
| Range | fixed |
| Thread | 1/8NPT |
| Contact | N.O./N.C. |
| Type | SPDT |
| Voltage / amps | 125/250VAC 10 / 30VDC 5 |
| Set pt | R/F |
| OAL | 3.7" |
| Electrical connection | DIN 43650A (connector ordered separately, see B151 p.76) |
What You'll Also Need
- DIN-style switches: DIN 43650 form A connector MCC2510A or cable 35732-1 / 35732-2 (15 ft) (B151 p.76).
- Deutsch-connector switches: harness 35559 or 35597 (25 ft, 2-way) (B151 p.75).
Before You Order
- Check both the set point and the direction: B151 lists switches that actuate on rising pressure (e.g. 26772 225 psi) and on falling pressure (p.62).
- Match the contact to the controller input: N.O., N.C. or SPDT (both) (B151 p.62–67).
- Check the port: most fixed-set Bijur switches are 1/8NPT, higher-range ones 1/4NPT, and 34241-8823 is M10x1 (B151 p.62–63).
- Check the electrical rating against the load; B151 ratings run from 250 mA (29921, 18–36 VDC) to 15 A (26792, 125–480 VAC) (p.63, 65).
Choosing Between Options
- SureFire II external end-of-line switches: PDI 26772-2 (225 psi); SLR 26641-2 single-phase or 27444-1 with MCC2510A on 3-phase (DS 36410, DS 36701).
- For adjustable high-pressure monitoring B151 lists 35517-1 (500–2000 psi) and 35517-2 (1200–4500 psi), Deutsch connection (p.62).
- Explosion-proof switches: SWT13299A (NEMA 4/7/9) and 24383 (NEMA 7/9, IP66) (B151 p.66).
Product Documentation
Opens in your browser — use your browser's save option to download a copy.
Browse all Bijur Delimon products or request a quote for 34210 — we reply the same day.