Product Overview
Bijur Delimon Meter Unit
Bijur Delimon 44949-1 Divider Valve Half MU-12R Grease
Part Number / SKU: 44949-1 | Manufacturer: Bijur Delimon | Availability: Made to Order - Lead Time: 70-80 business days
Overview
Bijur Delimon 44949-1 (factory description: DIVIDER HALF MU-12R GREASE). Bijur single-line resistance (SLR) meter units: small fixed-orifice fittings that split each oil shot from a cyclic lubricator between bearing points, each with its own inlet filter and outlet check valve.
Specifying, quoting, or replacing 44949-1
Add to cart at the price shown, or use the Request a Quote form: send the part number 44949-1, the quantity, and a photo of the nameplate or the old part, and we reply the same day. L. DeWitt McCarter is an authorized Bijur Delimon, Farval and LubeSite distributor in San Antonio, TX — (210) 494-1997.
Key Specifications
| Manufacturer part number | 44949-1 |
| Brand | Bijur Delimon |
| Selling unit | Each (1 piece) |
What You'll Also Need
- For junction-type units (FJB/FJC/FJD): Junction bars: die-cast 5/16-24 B3262 to B3471 (single) or B3109 to B4025 (double) for FJB/FJC; aluminum B4498 to B3772 or B3785 to B3789 for FJD (B151 p.52-55)
- 5/32 in tube connections: compression nut B1095 or bushing B1371 with sleeve B1061 (metal tube) or B8272 (nylon tube) (B151 p.18-19)
- A 25 µm line filter in the main line near the lubricator whenever meter units are used: 19850 (1 in) or 19848 (3 in) (DS 24117)
- FJB starter kits with units, junction bar, fittings and 5N25 tube: 32567 (4 points), 32568 (6 points), 32569 (8 points) (B151 p.37)
Before You Order
- Factory description: grease divider-valve half or distributor block (MU-xx). This is not an SLR oil meter unit from DS 35470 and does not interchange with F/A/M units.
- Meter units are for cyclic lubricators only (L2P, L5P, L5H, L18P, HAP-P, TM-1, TMD-5). V5B, V5W and V5 continuous pumps need Type C control units (DS 35470; DS 36734).
- Stay inside the lubricator's max total system flow (ø) table: L2P max 60 Type F units, L5P/L18P max 70; the TM-1 table stops at 20 units (DS 24797; DS 21967; DS 35477).
- Units feed one way only: fit them with the arrow stamped on the body pointing toward the bearing (DS 35470).
- Metric A-units use M8x1, 'very close to' but not the same as 5/16-24: use M8x1 bars 20348-x with AJB, 5/16-24 bars with F-units (DS 35470; B151 p.52-54).
- Converting to a SureFire II pump: system pressure must reach about 10 psi to open the 5 lb meter-unit check valves (TS015).
Choosing Between Options
- Standard rates are 00 to 3; 3/0 and 5 are for special situations. Each step up in rate doubles the oil to that point (DS 35470).
- FJB (junction mount, 5/32 in tail tube) is the most used type; FJC takes a 3/32 in tail tube; FJD is a thinner, closer-spaced unit with a 1/4-28 outlet (DS 35470).
- FSA/FSB screw into the bearing tap (1/8 NPT / 1/8 BSPT); FKA/FKB/FKD/FKE insert into a tapped drilled passage with no tubing (DS 35470).
- FRA/FRC take oil from a pressurized drilled passage (1/8 NPT in) out to a tail tube; FB and FT tee types work with junction headers (DS 35470).
Product Documentation
Opens in your browser — use your browser's save option to download a copy.
Browse all Bijur Delimon products or request a quote for 44949-1 — we reply the same day.