Authorized distributor in Live Oak, Texas · Parts ship direct from the manufacturer · International shipping to Canada, Mexico & Latin America · Call (210) 494-1997

Realizamos envíos a México, Colombia, Perú y toda Latinoamérica.

Bijur Delimon 55105 Flow Sensor-NPT

Bijur Delimon

(No reviews yet) Write a Review
MSRP: $342.55
$312.41
(You save $30.14 )
SKU:
55105
Availability:
Made to Order - Lead Time: 60-70 business days
Shipping:
Calculated at Checkout
Product Family:
Controls & Monitoring
Manufacturer:
Bijur Delimon
Adding to cart… The item has been added
Request a Quote We reply by email with price, lead time and freight.

Lead times & ordering

  • This item: Made to Order - Lead Time: 60-70 business days
  • Stocked items typically ship in 3–5 business days, direct from the manufacturer. Ship dates are confirmed on your quote.
  • Purchase orders accepted — net terms on approval. Credit card and wire also welcome.

Product Overview

Bijur Delimon Controls & Monitoring

Bijur Delimon 55105 Flow Sensor-NPT

Part Number / SKU: 55105  |  Manufacturer: Bijur Delimon  |  Availability: Made to Order - Lead Time: 60-70 business days

Overview

Bijur Delimon 55105 (factory description: FLOW SENSOR-NPT). Limit, proximity, cycle, flow and differential-pressure switches and sensors (with their cables and brackets) that monitor lubrication pumps, divider valves and lube points.

Specifying, quoting, or replacing 55105

Add to cart at the price shown, or use the Request a Quote form: send the part number 55105, the quantity, and a photo of the nameplate or the old part, and we reply the same day. L. DeWitt McCarter is an authorized Bijur Delimon, Farval and LubeSite distributor in San Antonio, TX — (210) 494-1997.

Key Specifications

Manufacturer part number55105
BrandBijur Delimon
Selling unitEach (1 piece)
Catalog listingLube Point Monitor (55105 series)
Thread1/8NPT
FunctionOval-gear flow monitor; approx. 0.65 cc (0.040 cu in) per pulse; 0–2500 cc/min
Max pressure10,153 psi (700 bar)
ElectricalM12 4-pole; reed switch 0–24 VDC, 0.20 A max; IP67
Lubricant / tempISO VG 32 oil to NLGI #2 grease; -20 to 70°C (-4 to 158°F)
Versions55105 1/8 NPT aluminum; 55105-B 1/8 BSPP; 55105-SS 1/8 NPT 316 SS; 55105-BSS 1/8 BSPP 316 SS

What You'll Also Need

  • M12 sensors need a matching M12 female cable; B151 lists 3-, 4-, 5- and 8-pole cables with different voltage limits (p.77).

Before You Order

  • Needs proper filtration (e.g. in-line grease strainer); cable sold separately, 76928-2863 straight 10 m or 76928-2833 90° 10 m (DS 35978).
  • Rebuild kit 55381 (DS 35978).
  • Match PNP or NPN output to the PLC input: 66925-1311 is N.O. PNP (PVB/PVBM), 66925S003 is N.O. NPN (M2500G), both 10–30 VDC (B151 p.47).
  • Match enclosure to the area: U625 is NEMA 7/9 explosion-proof; U10623 NEMA 1; 201132 and 17324 NEMA 4 (B151 p.47).
  • Cycle and limit switches are specific to a divider or pump model (e.g. FT15801C8 for 3000 series, 17324 for M2500G, 201134 only for DM61300C/DM62300C) (B151 p.47).

Product Documentation

Opens in your browser — use your browser's save option to download a copy.

Browse all Bijur Delimon products or request a quote for 55105 — we reply the same day.

Reviews