Overview
Bijur Delimon B3370 (factory description: MU MJC-5). Bijur single-line resistance (SLR) meter units: small fixed-orifice fittings that split each oil shot from a cyclic lubricator between bearing points, each with its own inlet filter and outlet check valve.
Specifying, quoting, or replacing B3370
Add to cart at the price shown, or use the Request a Quote form: send the part number B3370, the quantity, and a photo of the nameplate or the old part, and we reply the same day. L. DeWitt McCarter is an authorized Bijur Delimon, Farval and LubeSite distributor in San Antonio, TX — (210) 494-1997.
Key Specifications
| Manufacturer part number | B3370 |
| Brand | Bijur Delimon |
| Selling unit | Each (1 piece) |
| Symbol (factory description) | MJC-5 |
| Thread family / check valve | Inch thread; 1.25 lb outlet check valve (letter M) |
| Style | Junction type: threads into a junction or junction bar; tail tube runs to the bearing (letters -JC) |
| Outlet | 5/16-24 with tubing insert for a 3/32 in tail tube (-JC definition) |
| Flow rate | 5 = Extra, extra fast |
| Use with | Cyclic lubricators only; not continuous pumps |
| How it works | Inlet filter + fixed orifice & pin restrictor + outlet check valve |
| System type | Cyclic single-line resistance (SLR) oil systems |
| Flow direction | One direction only; arrow stamped on body |
| Rate codes | 3/0, 00, 0, 1, 2, 3, 4, 5 (slow to fast); each step doubles flow |
| Identification | Letter/number symbol stamped on the flat of the hex body |
What You'll Also Need
- For junction-type units (FJB/FJC/FJD): Junction bars: die-cast 5/16-24 B3262 to B3471 (single) or B3109 to B4025 (double) for FJB/FJC; aluminum B4498 to B3772 or B3785 to B3789 for FJD (B151 p.52-55)
- 5/32 in tube connections: compression nut B1095 or bushing B1371 with sleeve B1061 (metal tube) or B8272 (nylon tube) (B151 p.18-19)
- A 25 µm line filter in the main line near the lubricator whenever meter units are used: 19850 (1 in) or 19848 (3 in) (DS 24117)
- FJB starter kits with units, junction bar, fittings and 5N25 tube: 32567 (4 points), 32568 (6 points), 32569 (8 points) (B151 p.37)
Before You Order
- MJC part numbers are not in the DS 35470 tables (only MJ-00/1/2/5 are). Specs shown come from the symbol letters; confirm fit with the unit being replaced.
- Meter units are for cyclic lubricators only (L2P, L5P, L5H, L18P, HAP-P, TM-1, TMD-5). V5B, V5W and V5 continuous pumps need Type C control units (DS 35470; DS 36734).
- Stay inside the lubricator's max total system flow (ø) table: L2P max 60 Type F units, L5P/L18P max 70; the TM-1 table stops at 20 units (DS 24797; DS 21967; DS 35477).
- Units feed one way only: fit them with the arrow stamped on the body pointing toward the bearing (DS 35470).
- Metric A-units use M8x1, 'very close to' but not the same as 5/16-24: use M8x1 bars 20348-x with AJB, 5/16-24 bars with F-units (DS 35470; B151 p.52-54).
- Converting to a SureFire II pump: system pressure must reach about 10 psi to open the 5 lb meter-unit check valves (TS015).
Choosing Between Options
- Standard rates are 00 to 3; 3/0 and 5 are for special situations. Each step up in rate doubles the oil to that point (DS 35470).
- FJB (junction mount, 5/32 in tail tube) is the most used type; FJC takes a 3/32 in tail tube; FJD is a thinner, closer-spaced unit with a 1/4-28 outlet (DS 35470).
- FSA/FSB screw into the bearing tap (1/8 NPT / 1/8 BSPT); FKA/FKB/FKD/FKE insert into a tapped drilled passage with no tubing (DS 35470).
- FRA/FRC take oil from a pressurized drilled passage (1/8 NPT in) out to a tail tube; FB and FT tee types work with junction headers (DS 35470).
Product Documentation