Product Overview
Bijur Delimon SureFire II Lubricator
Bijur Delimon SFX35224-230 Lubricator SFX2 PDI Hartness 230 VAC
Part Number / SKU: SFX35224-230 | Manufacturer: Bijur Delimon | Availability: Made to Order - Lead Time: 20-30 business days
Overview
Bijur Delimon SFX35224-230 (factory description: LUB SFX2 PDI HARTNESS 230VAC). SureFire II is a self-contained electric gear-pump lubricator. PDI versions feed injectors with oil or fluid grease; SLR versions feed resistance meter units with oil; each serves up to 100 lube points.
Specifying, quoting, or replacing SFX35224-230
Add to cart at the price shown, or use the Request a Quote form: send the part number SFX35224-230, the quantity, and a photo of the nameplate or the old part, and we reply the same day. L. DeWitt McCarter is an authorized Bijur Delimon, Farval and LubeSite distributor in San Antonio, TX — (210) 494-1997.
Key Specifications
| Manufacturer part number | SFX35224-230 |
| Brand | Bijur Delimon |
| Selling unit | Each (1 piece) |
| Pump type | Self-contained electric motor-driven gear pump |
| Lube points served | Up to 100 (PDI injectors or SLR resistance fittings) |
| Outlets | 2x G 1/4 BSPP female, one each side of top plate; 2 plugs supplied for the unused side |
| Main feed line | 6 mm O.D. minimum recommended |
| Operating temperature | 40 °F to 105 °F (5 °C to 40 °C) |
| Oil fill screen | 40 mesh, removable (oil versions only) |
What You'll Also Need
- PDI builds: ZEM injectors (DS 35135), 0.01-1.5 cc per outlet; pump must reach 220 psi (15 bar) at the injector, 300 psi (21 bar) recommended.
- SLR builds: meter units (resistance fittings) - offered in 8 resistance levels for flow ratios up to 1:128 (FL 36979).
- Tubing: 6 mm O.D. nylon main line; 4 mm O.D. nylon from injectors or meter units to the lube points (FL 36979).
- Pump outlet fitting AR397 (6 mm tube x 1/4 BSPP) with copper washer 35010 (Catalog B151 p.83-84).
- Optional end-of-line pressure switch: PDI 26772-2 (225 psi); SLR single-phase 26641-2 (55 psi); SLR 3-phase 27444-1 + DIN connector MCC2510A (DS 36410; DS 36701).
Before You Order
- This is a special or legacy build number that is not decoded by the SFX ordering grid. Match the complete P/N on the pump nameplate before ordering or replacing.
- Mount upright only, at the lowest point of the lube network, so trapped air can migrate to line ends; trapped air can stop PDI injectors working (Manual 36412 p.3).
- AC single-phase motors are S3 20 %: max 2 min 59 s on per cycle and off time at least 4x on time. 24 VDC and 3-phase motors are S1 continuous (Manual 36412 p.5; QS 36711).
- Fluid grease (NLGI 000-00, max 40,000 cSt) is PDI only; SLR builds are oil only (DS 36410 p.4).
- Single-phase: motor overload protection is not built in - provide it from the host machine; also fit a disconnect per IEC 60947-1/-3 and an RCD (DS 36410 p.3; Manual 36412 p.4).
- Dirty oil is the most common cause of gear-pump failure: fill through the 40-mesh screen and inspect it every 4-5 fills (Manual 36412 p.48).
Choosing Between Options
- PDI (code B) runs ZEM injectors with oil or fluid grease at 450 psi (31 bar); SLR (code A) runs meter units with oil at 75 psi (1-phase) or 130 psi (3-phase) (DS 36410; DS 36701).
- Controls: terminal block (X/A) for PLC control; Timer (B) monitors level only; Lite (C) adds pressure- or cycle-switch monitoring; Premium (D) adds air pressure, oil streak, pre-lube, event (DS 36410 ordering grid; Manual 36412).
- Replacing a TM-5: special SureFire II SFX71322-RK (110/220 VAC) or SFX71322-BK (24 VDC) delivers a fixed 2.5 cc per cycle to existing meter units (TS020).
- Replacing AA/AB mechanical pumps: SureFire II package 71800-[voltage][size][material]J with one ZEM39 1.5 cc injector feeding the existing meter units (TS015).
Product Documentation
Opens in your browser — use your browser's save option to download a copy.
Browse all Bijur Delimon products or request a quote for SFX35224-230 — we reply the same day.