Product Overview
Bijur Delimon Divider Valve
Bijur Delimon ZVB04A153421 Lubricator ZV-B 4 Outlets
Part Number / SKU: ZVB04A153421 | Manufacturer: Bijur Delimon | Availability: Made to Order - Lead Time: 40-50 business days
Overview
Bijur Delimon ZVB04A153421 (factory description: LUB ZV-B 4 OUTLETS). Delimon ZV-B dual-line distributors (1-8 outlets) that meter grease or oil to each lube point from two alternately pressurized main lines, plus their adjusting-device and seal kits.
Specifying, quoting, or replacing ZVB04A153421
Add to cart at the price shown, or use the Request a Quote form: send the part number ZVB04A153421, the quantity, and a photo of the nameplate or the old part, and we reply the same day. L. DeWitt McCarter is an authorized Bijur Delimon, Farval and LubeSite distributor in San Antonio, TX — (210) 494-1997.
Key Specifications
| Manufacturer part number | ZVB04A153421 |
| Brand | Bijur Delimon |
| Selling unit | Each (1 piece) |
| Order code | ZVB04A153421 |
| Outlets | 4 (G 1/4) |
| Body material | Steel |
| Metered volume | 1.5 cm³ max per outlet per stroke |
| Metering (code 34) | Adjusting device with motion indicator, 3+4 outlets |
| Dose adjustment | Infinitely variable; minimum about 1/4 of maximum |
| Accessory (code 21) | Weld-on plate (SMS standard) for 3 and 4 outlets, incl. fixing screws |
| Max working pressure | 400 bar |
| Min actuating pressure | 10 bar |
| Metered volume options | 0.5, 1.5 or 3.0 cm³ per stroke |
| Actuating volume | 0.3 cm³ |
| Connections | Main lines G 3/8 (2 per face, 2 faces); outlets G 1/4 |
| Temperature | -20 to +70 °C with electrical monitoring; -20 to +120 °C without |
| Lubricants (mineral-oil based) | Grease to NLGI 3 (DIN 51818); oil ISO VG 68-1500 |
| Design | No springs; one metering + one control piston per 2 outlets |
What You'll Also Need
- A dual-line pump and reversing valve: main line I must be relieved while line II is pressurized, and vice versa (P_2018_1_GB_ZVB p.2).
- BS-B electric lubricator: BDI's data sheet names ZV-B distributors as its usual downstream partner in dual-line systems (DS 35515 p.1).
- Weld-on plate (SMS standard) if needed: accessory code 20 (1-2 outlets), 21 (3-4), 22 (5-6), 01 (7-8) (P_2018_1_GB_ZVB p.5).
- Electrical monitoring: see BDI data sheets 66925P1 (monitoring switch) and 66925S001 (inductive sensor) (P_2018_1_GB_ZVB p.4).
Before You Order
- Never pressurize above 400 bar - BDI warns this is a danger to life and limb (P_2018_1_GB_ZVB p.4).
- Metering screw = fixed maximum dose. Order an adjusting device (codes 32-35, 42-45, 09) if the dose must change later; minimum is about 1/4 of maximum (P_2018_1_GB_ZVB p.5).
- The metering and plate codes must match the outlet-pair group: 1+2, 3+4, 5+6 or 7+8 outlets (P_2018_1_GB_ZVB p.5).
- To cross-port or separate two facing outlets, the set screw (6) and screw plug (7) must be removed or fitted (P_2018_1_GB_ZVB p.3).
- With electrical monitoring the limit is -20 to +70 °C; without (with protection cap) -20 to +120 °C (P_2018_1_GB_ZVB p.4).
Choosing Between Options
- 0.5, 1.5 or 3.0 cm³ per stroke (codes 05/15/30); each outlet is served once per full cycle of two lubricating strokes (P_2018_1_GB_ZVB p.2, p.5).
- Body: steel (codes 01-08), stainless 1.4305 (E1-E8) or stainless 1.4404 (F1-F8) (P_2018_1_GB_ZVB p.5).
- ZV-B (400 bar) vs Farval DD/DM dual-line valves (3500 psi / 240 bar max) (P_2018_1_GB_ZVB p.4; DS 35513 p.2).
Product Documentation
Opens in your browser — use your browser's save option to download a copy.
Browse all Bijur Delimon products or request a quote for ZVB04A153421 — we reply the same day.